Differences between revisions 12 and 27 (spanning 15 versions)
Revision 12 as of 2011-05-29 13:44:05
Size: 977
Editor: PieterSmit
Comment: Add Builders tanks
Revision 27 as of 2019-02-02 11:08:02
Size: 2776
Editor: PieterSmit
Comment:
Deletions are marked like this. Additions are marked like this.
Line 6: Line 6:
 * http://www.raincell.co.za/ - beautiful. water tank. [[http://www.raincell.co.za/accessories/accessories.asp|accessories]]  * 2019 NZ Legal rain water harvesting
   * https://www.watercare.co.nz/Help-and-advice/Be-Waterwise/Collecting-rainwater
     1. Need concent if tank over 6000l
     1. Need concent if plumbing into home. (Not just outside usage)
     * planner at Auckland Council: phone (09) 301 0101.
 * 2019 - http://www.level.org.nz/water/water-supply/mains-or-rainwater/harvesting-rainwater/
 * 2019 - https://www.rainline.co.nz/
 * 2019 - [[attachment:VERGE-rainwater-withnewlinks.jpg]]
   * Tank design
     1. 1st Flush 10min
     1. Leaf catcher
     1. Quiet inlet - to not disturb bottom silt
     1. Outlet taking water 100mm+ above bottom
 * 2019 - http://www.yourhome.gov.au/water/rainwater
 * 2018 - Store water in concrete slab foundation - https://www.aquacomb.co.nz/
 * 2018 - Ydrostop - automatic burst/leak water shutdown http://www.ydroteq.be/en/products/ydrostop-water-control-valve/
 * Turbine https://youtu.be/XiefORPamLU
 * Link [[eco/WaterEnergyStorage]] , [[attachment:Water-ZA-2014.pdf|South African Water usage 2014]]
 * [[http://www.baur-research.com/irrigator/price.html|Baur]] irrigation based on soil moisture.
 * [[http://www.wetec.co.za/article.php?a_id=20|Wetec]] How to install a complete rain harvesting system
 * http://www.raincell.co.za/ - beautiful. water tank. [[http://www.raincell.co.za/accessories/accessories.asp|accessories]] 011-817-3534
   * 2000l 2.1m x 1.9m x 0.8m @ R3800
Line 17: Line 38:
 * Circulate hot water to keep tap hot, reducing waste while waiting for water to heat.
   1. At taps circulate hot water back into cold until heated.
Line 18: Line 41:
== Water Harvesting components ==
 * Leafe catcher
 * First flush diverters are typically sized to divert about 10L per 50m2 of roof plan area
 * Bug filters into the tank
 * Slow-release into the tank, horizontal T above the bottom
 * Overflow retrieving water from the bottom of the tank
 * Drain valve
 * Pressure booster pump

Water

Water Harvesting components

  • Leafe catcher
  • First flush diverters are typically sized to divert about 10L per 50m2 of roof plan area
  • Bug filters into the tank
  • Slow-release into the tank, horizontal T above the bottom
  • Overflow retrieving water from the bottom of the tank
  • Drain valve
  • Pressure booster pump

...


CategoryEcoFriendly

eco/water (last edited 2019-02-02 11:08:02 by PieterSmit)