Differences between revisions 13 and 14
Revision 13 as of 2018-04-21 22:41:48
Size: 1799
Editor: PieterSmit
Comment:
Revision 14 as of 2018-04-21 23:12:56
Size: 2059
Editor: PieterSmit
Comment:
Deletions are marked like this. Additions are marked like this.
Line 10: Line 10:

 * Windows - double glazing with Low-e reflective coating to reflect infrared heat back.
   * Insulated frames, especially aluminium frames need a thermal break

 * Wall insulation
   * https://www.energywise.govt.nz/at-home/insulation/wall-insulation/

Eco friendly building

Design ideas / principles

  • Eave overhang: A general rule of thumb for the depth of your eave is 45% of the height of your window (this is the measurement from the bottom of your window to the underside of the eave). From: Green Homes Nz

  • Thermal mass as energy stabiliser - Water has the highest VHC of these and the table tells us that it takes 4186KJ to raise the temperature of one cubic meter of water by one degree, whereas it only takes 2060KJ to raise the temperature of an equal volume of concrete by the same amount.

  • Windows - double glazing with Low-e reflective coating to reflect infrared heat back.
    • Insulated frames, especially aluminium frames need a thermal break
  • Wall insulation

Adhoc items for the home

* http://www.greenbuildingadvisor.com/blogs/dept/musings/green-building-beginners

Heat mass

  • .A simplistic rule of thumb that is often used when designing dense masonry walls, is that heat will be absorbed and lost at around an inch per 2 hours. i.e a 4inch (100mm) thick masonry wall will absorb and shed its heat load in around 8 hours and a 8inch (200mm) thick wall in around 16 hours.


CategoryEcoFriendly

eco/building (last edited 2018-06-17 21:49:00 by PieterSmit)