* Remotely managed through network SNMP and possibly WEB * Status & Events, on-line, off-line, battery problems (SNMP and TRAPS) * Multiple input's * Escom power from grid * Solar from panels * Wind ? * GenSet * External battery's * Either modular, or capable of adding external lead-acid battery's * Remote power control, or scheduled control * Capable of switching off certain outlets * Battery management * Protection against damage due to full discharge * Measurement and reporting on quality/status/life of battery unit * Environmental * Temperature etc. that could reduce battery life. * Capable of operating at high temperatures e.g. 65C |
* Critical * Remotely managed through network SNMP and possibly WEB * Status & Events, on-line, off-line, battery problems (SNMP and TRAPS) * Multiple input's * Escom power from grid * Solar from panels * Wind ? * GenSet / Autostart * Prefered * External battery's * Either modular, or capable of adding external lead-acid battery's * Battery management * Protection against damage due to full discharge * Measurement and reporting on quality/status/life of battery unit * Nice to have * Remote power control, or scheduled control * Capable of switching off certain outlets * Environmental * Temperature etc. that could reduce battery life. * Capable of operating at high temperatures e.g. 65C |
UPS Un-Interruptible power supply
- Normally achieved with a battery backup.
- see
The main focus here is to look at requirements for a UPS at a small remote branch or remote site.
Requirements / Ideal
- Critical
- Remotely managed through network SNMP and possibly WEB
Status & Events, on-line, off-line, battery problems (SNMP and TRAPS)
- Multiple input's
- Escom power from grid
- Solar from panels
- Wind ?
GenSet / Autostart
- Remotely managed through network SNMP and possibly WEB
- Prefered
- External battery's
- Either modular, or capable of adding external lead-acid battery's
- Battery management
- Protection against damage due to full discharge
- Measurement and reporting on quality/status/life of battery unit
- External battery's
- Nice to have
- Remote power control, or scheduled control
- Capable of switching off certain outlets
- Environmental
- Temperature etc. that could reduce battery life.
- Capable of operating at high temperatures e.g. 65C
- Remote power control, or scheduled control
Home Made UPS
Aviosys power monitoring unit with network connection + relay's
South African Company's
- GSM-Tronix
- Meisner
...